LG Therma V fault CH14
Problem in flow rate
Heat pumpWhat it means
Low flow detection during pump operation, indicating insufficient water flow through the system during circulation pump operation.
Likely causes
- Flow sensor is electrically open
- Water pump is in trouble/failed
- Flow switch is electrically open
- Flow switch contact is mechanically broken
- Particles in water quality causing locking at the shaft of the water pump
- Air trapped inside the unit (air not vented)
- Strainer / water pipe clogging
- Poor setting of external pump installation
- Circulation pump malfunction
- Cable interference around the flow sensor causing false switch state detection
- Use of compressed air or oxygen for leak testing
Where to start
- Step 3: If pressure OK, check water pump still running (vibration test at terminal box, or 'Water Pump Operating' on control panel) - if NO, investigate flow sensor (branch B)
- Step 4: If pump running, check if control panel shows CH14 - if NO, condition is normal (END); if YES, investigate water pump trouble (branch C)
- Touch the terminal box (black plastic box at the water pump) and feel if the water pump is vibrating
The full answer, free
- 15 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 85), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the LG manual for the Therma V. Check the model on the data plate before you order parts.
Other LG Therma V fault codes
- 03Communication error between indoor unit and wired remote controller
- 05Communication error between main PCB(indoor) and main PCB(outdoor cycle)
- 14Problem in flow rate
- 15Overheating of water pipe
- 232Problem in flow sensor
- 26No position error
- 29Comp over current
- 40Inv comp CT sensor error
- 52Inv PCB(outdoor) - main PCB(outdoor cycle) communication error
- 53Main PCB(indoor) - main PCB(outdoor) communication error
- 57Main PCB(indoor) → inv PCB(outdoor) communication error
- 60Outdoor EEPROM error
- 67Fan lock error
- CH01Room air temperature sensor fault
- CH02Inlet pipe temperature sensor fault
- CH03Bad communication between remote controller and indoor unit
- CH05Bad communication between outdoor unit and indoor unit
- CH08DHW tank temperature sensor fault
- CH09PCB program (EEPROM) fault
- CH114Injection in sensor error
- CH115Injection out sensor error
- CH13DHW tank temperature sensor fault
- CH15Water pipe strange overheat
- CH16Problems in sensors (heater water temperature sensor error)