Samsung EHS fault 162
Outdoor UNIT EEPROM error
Heat pumpFree account: the manual page (page 50). No card needed.See the full 162 answer
What it means
Outdoor unit EEPROM error (Samsung code table). The outdoor unit EEPROM sits on connector CN200 of the outdoor main PCB.
Likely causes
- Defective EEPROM
- Short or dewetting between EEPROM pins
- Communication failure between EEPROM and MICOM
- Incorrect or corrupted EEPROM option settings
- EEPROM fault
Where to start
- Check for a short or a dry joint (dewetting) between the EEPROM pins. If you find one, replace the PCB.
- If the pins are fine, re-enter the model options and do a power reset. If the error comes back, replace the PCB.
The full answer, free
- How to put it right, step by step
- The manual page for this fault (page 50), right under the answer
Safety: Isolate the heat pump and any backup heater, and give any inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
Full 162 fix, readings and manual page. Free.See the full answer
From the Samsung manual for the EHS. Check the model on the data plate before you order parts.
Other Samsung EHS fault codes
- 108Setting address duplicate error
- 121Error of ROOM temperature sensor in indoor unit short/open
- 122Error of Evaporator_in sensor of indoor unit short/open
- 123Error of Evaporator_out sensor of indoor unit short/open
- 201CONTROL KIT / outdoor UNIT communication error (matching error)
- 202CONTROL KIT / outdoor UNIT communication error
- 203Communication error between indoor / outdoor INV <-> MAIN MICOM
- 221Outdoor temperature sensor error (open/short)
- 231COND_OUT main temperature sensor error (open/short)
- 251Discharge temperature sensor error (open/short)
- 276Compressor top temperature sensor error (open/short)
- 308Suction sensor error (open/short)
- 321EVI inlet sensor error (open/short)
- 322EVI outlet sensor error (open/short)
- 458Outdoor unit fan error
- 462All currency control COMP stop or CT2 low currency
- 463OLP over heat and comp stop
- 464[inverter] DC peak error
- 466[inverter] DC-link voltage under/over error
- 467COMP revolute error
- 475Outdoor unit BLDC fan error
- 507Comp down due to high pressure or high pressure switch open
- 554GasLeak error
- 590[inverter] data flash error