Samsung EHS fault 203

Communication error between indoor / outdoor INV <-> MAIN MICOM

Heat pump
Free account: the readings and the manual page (page 77). No card needed.See the full 203 answer

What it means

Error 203 is displayed on MAIN PCB when INVERTER PCB shows ALL OFF status, indicating a wire/socket connection fault, blown fuse on INVERTER PCB, BLDC fan motor short, or INVERTER PCB fault. Part of the outdoor unit power supply error diagnostic group.

Likely causes

  1. Communication or power cable between the MAIN PBA and INVERTER PBA not connected properly
  2. Faulty MAIN PBA or INVERTER PBA

Where to start

  1. Check the communication and power cable between the MAIN PBA (CN305) and the INVERTER PBA (CN31) is connected properly.
  2. If the error stays, replace the MAIN PBA, then the INVERTER PBA.

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 77), right under the answer

Safety: Isolate the heat pump and any backup heater, and give any inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

Full 203 fix, readings and manual page. Free.See the full answer

From the Samsung manual for the EHS. Check the model on the data plate before you order parts.