Triton T90SR fault 5
During use, the water flow ceases abruptly
Electric showerWhat it means
Water flow stops suddenly during use, caused by interrupted power supply, solenoid valve malfunction, or faulty pump motor.
Likely causes
- Solenoid valve malfunction - pump still operates (5.2)
- Pump motor faulty (5.3)
Where to start
- Observe if pump still operates while flow has stopped (indicates solenoid valve malfunction)
- Open the bleed screw on the pump unit by rotating two revolutions
- Observe for water flow from the opening to confirm trapped air is vented and pump is primed
The full answer, free
- How to put it right, step by step
- The manual page for this fault (page 26), right under the answer
Safety: Isolate at the double pole isolator and the consumer unit, and prove dead before the cover comes off. Electrical work to BS 7671 (UK) or I.S. 10101 (Ireland).