Worcester Bosch Greenstar 2000 fault 224

Flue gas or heat exchanger temperature limiter tripped

Gas boiler
Free account: 2 more checks, the readings and the manual page (page 65). No card needed.See the full 224 answer

What it means

The flue gas temperature limiter or the heat exchanger temperature limiter has tripped. Blocking fault (B); if it stays for a long time it becomes a locking fault (V).

Likely causes

  1. Isolation valve in the heating circuit closed.
  2. Low water pressure.
  3. Broken heat exchanger temperature limiter or connecting lead.
  4. Broken flue gas temperature limiter or connecting lead.
  5. Air in the appliance.

Where to start

  1. Check the position of the isolation valve in the heating circuit and open it if required.
  2. Check the water pressure and top up until the preset pressure is reached.
  3. Check the heat exchanger temperature limiter and its connecting lead for breaks.

The full answer, free

  • 2 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 65), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 224 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar 2000. Check the model on the data plate before you order parts.