Worcester Bosch Greenstar 2000 fault 264

Air feed failed during operating phase

Gas boiler
Free account: 1 more check, the readings and the manual page (page 67). No card needed.See the full 264 answer

What it means

The air supply (fan) failed while the burner was running.

Likely causes

  1. Fan plug not properly connected.
  2. Faulty fan.
  3. Incorrect mains voltage.
  4. Blockage in the flue system.
  5. Blocked venturi/injector.

Where to start

  1. Check the fan plug connection.
  2. Check the mains voltage against the rated value.
  3. Check the flue system for blockages.

The full answer, free

  • 1 more check in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 67), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.