Worcester Bosch Greenstar 2000 fault 232

Heat source locked by external switching contact

Gas boiler
Free account: the manual page (page 66). No card needed.See the full 232 answer

What it means

The boiler is held off by an external switching contact. Blocking fault (B).

Likely causes

  1. External switching contact plug not connected.
  2. Condensate pump jumper not fitted.
  3. External temperature switch switching point does not suit the system.
  4. Faulty connecting lead to the external temperature switch.

Where to start

  1. Check the plug connection for the external switching contact.
  2. Check the condensate pump jumper is fitted to the manufacturer's specification.
  3. Check the switching point of the external temperature switch.

The full answer, free

  • How to put it right, step by step
  • The manual page for this fault (page 66), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 232 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar 2000. Check the model on the data plate before you order parts.