Worcester Bosch Greenstar 4000 Combi fault 233
Boiler identification module or device electronics faulty
Gas boilerFree account: the readings and the manual page (page 73). No card needed.See the full 233 answer
What it means
Category V locking fault: the control has found a fault with the boiler identification module (code plug) or the electronics.
Likely causes
- Wrong code plug inserted.
- Damaged code plug.
Where to start
- Check the code plug is the right one for the model and gas type (page 89).
- Check the code plug is not damaged (page 73).
The full answer, free
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 73), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full 233 fix, readings and manual page. Free.See the full answer
From the Worcester Bosch manual for the Greenstar 4000 Combi. Check the model on the data plate before you order parts.
Other Worcester Bosch Greenstar 4000 Combi fault codes
- 1010No communication via EMS BUS connection
- 1021Cylinder charging or hot water temperature sensor faulty
- 1037Outside temperature sensor faulty, heating backup operation active
- 1065System pressure sensor faulty or not connected
- 1068Outside temperature sensor or lambda probe faulty
- 1073Short circuit at flow temperature sensor
- 1074No signal from flow temperature sensor
- 1075Heat exchanger temperature sensor short circuit
- 1076Heat exchanger temperature sensor disconnected
- 2085Internal fault
- 214Fan shut down during safety time
- 224Maximum flue gas thermostat or heat exchanger maximum thermostat activated
- 228Flame signal without flame present
- 234Gas valve electrical fault
- 238Boiler electronics faulty
- 269Flame monitoring
- 281Pump stuck or running in air
- 2910Fault in flue system
- 2915Boiler electronics system fault (fan keeps running after post-purge)
- 2916Boiler electronics system fault (gas valve detected open during post-purge)
- 2923Boiler electronics system fault (unexpected feedback from modulating gas valve)
- 2927Flame failed during burner operation
- 2948No flame signal with low output
- 2949No flame signal with high output