Midea Heat pump fault E1
Phase loss or phase reversal
Heat pumpWhat it means
Error code E1 applies to 3-phase units and indicates phase loss or phase reversal, triggered when at least one of L1/L2/L3/N is misconnected or disconnected.
Likely causes
- At least one of L1/L2/L3/N misconnected or disconnected
- Incorrect phase sequence
- Faulty inverter control box
- Faulty inverter power module
- Faulty three-phase bridge rectifier (3Ph models)
Where to start
- Identify CN30 terminal block pins 1-10 (A, B, X/HA, Y/HB, E, T1, T2, E1, H1, H2)
- Confirm correct wiring of A, B, X/HA, Y/HB, E to external Modbus module terminals X1/HB, X2/HA, H1, H2
- Verify B-/A+/E connections to Modbus interface
The full answer, free
- 13 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 116), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Midea manual for the Heat pump. Check the model on the data plate before you order parts.
Other Midea Heat pump fault codes
- BAT4 sensor out of operation range protection
- C2IBH (internal backup heater) related fault
- C7Over-high temperature protection for IPM module
- D0Oil return operation active
- E0Water flow failure
- E5T3 outdoor unit heat exchanger bottom temperature sensor error
- E6T4 ambient temperature sensor error
- E8Water flow protection
- E9Th return-air temperature sensor error
- EALow discharge temperature protection
- ECT5_2 water tank temperature sensor error (reserved)
- F1Protection for DC bus undervoltage
- F75Protection for insufficient discharge overheating degree
- FC1TL outdoor unit heat exchanger outlet temperature sensor error
- H1Communication error between main control PCB and inverter PCB
- H2T2 plate heat exchanger outlet refrigerant temperature sensor error
- H3T2B plate heat exchanger inlet refrigerant temperature sensor error
- H4Repeated L1* protection (3 times in 60 mins)
- H5Ta room temperature sensor error
- H6DC fan motor protection
- H7Compressor voltage protection
- H8H-SEN high pressure sensor error
- H9Tw2 zone 2 water flow temperature sensor error
- HATw_out plate heat exchanger outlet water temperature sensor error