Samsung EHS fault E464
IPM (IGBT module) over current error (continued)
Heat pumpFree account: 1 more check, the readings and the manual page (page 70). No card needed.See the full E464 answer
What it means
Continuation of the E464 troubleshooting flowchart, covering compressor insulation resistance and temperature sensor checks leading to inverter PCB replacement if unresolved.
Likely causes
- Refrigerant not charged correctly
- Compressor not working normally
- Compressor connection wrong
- Obstacle around the indoor or outdoor unit
- Service valves not fully open
- Faulty inverter PCB
Where to start
- Check the outdoor and indoor units are installed to the installation manual with nothing obstructing them.
- Check the service valves are fully open.
- Check the compressor wires are connected correctly.
The full answer, free
- 1 more check in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 70), right under the answer
Safety: Isolate the heat pump and any backup heater, and give any inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
Full E464 fix, readings and manual page. Free.See the full answer
From the Samsung manual for the EHS. Check the model on the data plate before you order parts.
Other Samsung EHS fault codes
- 108Setting address duplicate error
- 121Error of ROOM temperature sensor in indoor unit short/open
- 122Error of Evaporator_in sensor of indoor unit short/open
- 123Error of Evaporator_out sensor of indoor unit short/open
- 162Outdoor UNIT EEPROM error
- 201CONTROL KIT / outdoor UNIT communication error (matching error)
- 202CONTROL KIT / outdoor UNIT communication error
- 203Communication error between indoor / outdoor INV <-> MAIN MICOM
- 221Outdoor temperature sensor error (open/short)
- 231COND_OUT main temperature sensor error (open/short)
- 251Discharge temperature sensor error (open/short)
- 276Compressor top temperature sensor error (open/short)
- 308Suction sensor error (open/short)
- 321EVI inlet sensor error (open/short)
- 322EVI outlet sensor error (open/short)
- 458Outdoor unit fan error
- 462All currency control COMP stop or CT2 low currency
- 463OLP over heat and comp stop
- 464[inverter] DC peak error
- 466[inverter] DC-link voltage under/over error
- 467COMP revolute error
- 475Outdoor unit BLDC fan error
- 507Comp down due to high pressure or high pressure switch open
- 554GasLeak error