Vaillant Gas boiler fault F.22
Safety shutdown: water deficiency
Gas boilerWhat it means
Safety shutdown due to insufficient or no water in the product.
Likely causes
- Filling pressure fallen below 0.05 MPa (0.5 bar)
- Water leak in heating system
- Frequent pressure drops due to unresolved leak or venting issue
- Insufficient/no water in the product.
- Interruption in the wiring harness
Where to start
- Check displayed pressure value on screen (flashes if below 0.1 MPa / 1.0 bar)
- Top up the heating water to restore pressure
- Monitor pressure value on display - it flashes until pressure of 0.11 MPa (1.1 bar) or higher is reached
The full answer, free
- 2 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 60), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
From the Vaillant manual for the Gas boiler. Check the model on the data plate before you order parts.
Other Vaillant Gas boiler fault codes
- F.00Flow temperature sensor interruption
- F.01Return temperature sensor interruption
- F.03Cylinder temperature sensor interruption
- F.10Flow temperature sensor short circuit
- F.11Return temperature sensor short circuit
- F.13Cylinder temperature sensor short circuit
- F.23Safety shutdown: temperature spread too great
- F.24Safety shutdown: temperature rise too fast
- F.25Safety shutdown: flue gas temperature too high
- F.27Safety shutdown: flame simulation
- F.32Fan fault
- F.33Air pressure switch fault
- F.64Fault: electronics/NTC
- F.65Electronics temperature fault
- F.72Flow and/or return temperature sensor fault
- F.74Water pressure sensor signal outside correct range (too high)
- F.75Pump fault/water deficiency
- F.77Accessory fault (flue non-return flap, condensate pump, etc.)
- F.83Flow and/or return temperature sensor temperature change fault
- F.84Temperature difference fault at the flow and return temperature sensors
- F.85Flow and return temperature sensors installed incorrectly (inverted)
- P.02Minimum load check programme
- S.42Flue non-return flap closed
- S.46Comfort protection: minimum load, loss of flame