Vaillant Gas boiler fault F.64
Fault: electronics/NTC
Gas boilerWhat it means
An electronics/NTC fault has been detected, typically due to a short circuit on flow or return NTC.
Likely causes
- Flow NTC short circuit.
- Return NTC short circuit
- PCB defective
Where to start
- Check that the flow NTC works correctly.
- Check that the return NTC works correctly.
The full answer, free
- How to put it right, step by step
- The manual page for this fault (page 62), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
From the Vaillant manual for the Gas boiler. Check the model on the data plate before you order parts.
Other Vaillant Gas boiler fault codes
- F.00Flow temperature sensor interruption
- F.01Return temperature sensor interruption
- F.03Cylinder temperature sensor interruption
- F.10Flow temperature sensor short circuit
- F.11Return temperature sensor short circuit
- F.13Cylinder temperature sensor short circuit
- F.22Safety shutdown: water deficiency
- F.23Safety shutdown: temperature spread too great
- F.24Safety shutdown: temperature rise too fast
- F.25Safety shutdown: flue gas temperature too high
- F.27Safety shutdown: flame simulation
- F.32Fan fault
- F.33Air pressure switch fault
- F.65Electronics temperature fault
- F.72Flow and/or return temperature sensor fault
- F.74Water pressure sensor signal outside correct range (too high)
- F.75Pump fault/water deficiency
- F.77Accessory fault (flue non-return flap, condensate pump, etc.)
- F.83Flow and/or return temperature sensor temperature change fault
- F.84Temperature difference fault at the flow and return temperature sensors
- F.85Flow and return temperature sensors installed incorrectly (inverted)
- P.02Minimum load check programme
- S.42Flue non-return flap closed
- S.46Comfort protection: minimum load, loss of flame