Worcester Bosch Greenstar 2000 fault 2941

Insufficient flow rate in heat source

Gas boiler
Free account: 2 more checks, the readings and the manual page (page 70). No card needed.See the full 2941 answer

What it means

The boiler has detected too little water flow through the heat source.

Likely causes

  1. Faulty flow temperature sensor plug.
  2. Faulty flow temperature sensor.
  3. Blocked pump.
  4. Incorrect pump settings.
  5. Low water pressure.

Where to start

  1. Check the flow temperature sensor plug.
  2. Check the flow temperature sensor.
  3. Check the pump for blockage.

The full answer, free

  • 2 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 70), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 2941 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar 2000. Check the model on the data plate before you order parts.