Worcester Bosch Greenstar 2000 fault 2962

No signal from fan

Gas boiler
Free account: 2 more checks, the readings and the manual page (page 71). No card needed.See the full 2962 answer

What it means

The boiler is getting no signal from the fan. The manual prints the same entry for 2961 and 2962.

Likely causes

  1. Fan not receiving mains voltage.
  2. Fan harness fault.
  3. PWM (pulse width modulation) signal fault.
  4. Faulty fan.
  5. Faulty PCB.

Where to start

  1. Check the mains voltage to the fan.
  2. Check the fan harness for continuity.
  3. Check the pulse width modulation (PWM) signal.

The full answer, free

  • 2 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 71), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 2962 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar 2000. Check the model on the data plate before you order parts.