Worcester Bosch Greenstar 2000 fault 2964

Insufficient flow rate in heat exchanger

Gas boiler
Free account: 2 more checks, the readings and the manual page (page 71). No card needed.See the full 2964 answer

What it means

The boiler has detected too little water flow through the heat exchanger.

Likely causes

  1. Supply (flow) sensor not fitted on the supply pipe.
  2. Supply sensor not making proper contact with the supply pipe.
  3. System not filled with water.
  4. No water flow because the CH system is closed.
  5. No water flow because the pump is not working correctly.

Where to start

  1. Check the supply sensor is fitted on the supply pipe.
  2. Check the supply sensor makes good contact with the supply pipe.
  3. Check the system is filled with water.

The full answer, free

  • 2 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 71), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.