Worcester Bosch Greenstar 2000 fault 342
Temperature increase in DHW mode too rapid
Gas boilerFree account: the readings and the manual page (page 67). No card needed.See the full 342 answer
What it means
The temperature is rising too fast in hot water mode.
Likely causes
- Water pressure too low.
- Service valves in the cylinder charging circuit closed.
- Faulty diverter valve or cylinder primary pump.
Where to start
- Check the water pressure; if low, top up and vent the system.
- Open the service valves in the cylinder charging circuit.
The full answer, free
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 67), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full 342 fix, readings and manual page. Free.See the full answer
From the Worcester Bosch manual for the Greenstar 2000. Check the model on the data plate before you order parts.
Other Worcester Bosch Greenstar 2000 fault codes
- 1013Maximum combustion point reached
- 1021DHW temperature sensor faulty
- 1065Pressure sensor faulty or not connected
- 1073Flow temperature sensor short circuit
- 1074No signal from the flow temperature sensor
- 1075Short circuit in heat exchanger temperature limiter
- 214Fan stops during safety time
- 215Fan too fast
- 224Flue gas or heat exchanger temperature limiter tripped
- 227No flame detected
- 228Flame signal present although burner switched off
- 232Heat source locked by external switching contact
- 233Fault in code plug or appliance electronics
- 234Electrical fault in gas valve
- 237System fault
- 242System fault, appliance electronics
- 244System fault, appliance electronics / basic controller
- 264Air feed failed during operating phase
- 269Flame monitoring
- 281Pump stuck or running dry
- 2910Fault in flue system
- 2917No flame signal when checking the combustion control
- 2925System fault, appliance electronics
- 2926System fault, appliance electronics