Worcester Bosch Greenstar 4000 Combi fault 2963

The heat exchanger sensor or both supply and heat exchanger sensors are defect

Gas boiler

What it means

Fault detected with the heat exchanger sensor or both supply and heat exchanger sensors.

Likely causes

  1. System not filled/air locked
  2. Faulty heat exchanger sensor (primary thermistor)
  3. Damaged harness

Where to start

  1. Check the flow through the appliance and the system is filled
  2. Check for air locks in the system and purge if required
  3. Check the heat exchanger sensor (primary thermistor) and the plug connected to temperature sensor

The full answer, free

  • 2 more checks in order
  • How to put it right, step by step
  • The manual page for this fault (page 78), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.