Daikin Altherma fault 8H-01
Overheating mixed water circuit
Heat pumpWhat it means
Water temperature in the mixed circuit is too high.
Likely causes
- Faulty outlet water thermistor for bizone
- Mixed water temperature exceeds [9-00] setting + 5K
- Faulty 3-way valve
- Faulty bizone PCB
- Deviation of thermistor (higher temperature measured than actual).
- Faulty room thermistor
- Bad contact between sensor and pipe
- Loose or disconnected wires
- Damaged connectors or wires
- Deviation of outlet water after backup heater thermistor (lower temperature measured than actual)
- Deviation of thermistor (lower temperature measured than actual)
- Bad contact between refrigerant loop and inverter heat sink
- Lack of refrigerant
- Open circuit winding
- Short circuit winding
- LD1 not flashing: no operation of LAN adapter
- LD2 flashing: TCP/IP communication problem with router
- LD3 flashing: communication problem between LAN adapter and indoor unit
Where to start
- Perform a check of the outlet water thermistor bizone
- Check the field setting [9-00]
- Perform a check of the 3-way valve
The full answer, free
- 23 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 25), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Daikin manual for the Altherma. Check the model on the data plate before you order parts.
Other Daikin Altherma fault codes
- 4-02Incorrect setting of space heating OFF temperature
- 7HFlow error (minimum flow rate not reached)
- 7H-01Water flow problem
- 7H-04Water flow problem during domestic hot water production
- 7H-05Water flow problem during heating/sampling
- 7H-06Water flow during cooling/defrost
- 7H-07Water flow problem. pump de-blocking active
- 7H-XXWater flow or volume too low
- 80-00Inlet water thermistor abnormality
- 81-00Outlet water thermistor abnormality
- 81-01Mixed water thermistor abnormality
- 89-01Heat exchanger frozen
- 89-02Heat exchanger frozen
- 89-03Heat exchanger frozen
- 8F-00Abnormal increase outlet water temperature (domestic hot water)
- 8H-00Abnormal increase outlet water temperature
- 8H-02Overheating mixed water circuit (thermostat)
- 8H-03Safety thermostat circuit open with jumper removed
- A1-00Zero cross detection problem
- A5-00Outdoor unit: high pressure peak cut / freeze protection problem
- AA-01Backup heater overheated
- AA-02External backup heater overheated
- AC-00Booster heater overheated
- AH-00Tank disinfection function not completed correctly