Ideal Logic System IE Gen 2 fault L02

Ignition lockout

Gas boiler
Free account: 4 more checks, the readings and the manual page (page 31). No card needed.See the full L02 answer

What it means

The boiler has failed to light after 5 ignition attempts and has locked out. It is a lockout (L) code; the ignition lockout flowchart is section 4.3.

Likely causes

  1. Low gas pressure.
  2. Gas valve wiring or PCB fault (no 24 Vdc at the gas valve).
  3. Faulty gas valve.
  4. Faulty spark generator.
  5. Faulty electrode.
  6. Blocked condensate or trap.

Where to start

  1. Press Restart (E) and watch whether the boiler ignites for a short time then goes out.
  2. Check the gas pressure at the boiler inlet is more than 18 mbar (test point H, page 31).
  3. Check there is approx 24 Vdc supply at the gas valve.