Ideal Logic System IE Gen 2 fault F02
Flame loss
Gas boilerWhat it means
Boiler has lost flame signal during operation, indicating ignition or gas supply issues.
Likely causes
- No/low gas pressure at boiler inlet
- Faulty electrode or harness
- Faulty spark generator or harness
- No 24Vdc supply to gas valve while flame is on
- Wiring fault from gas valve to PCB
- Faulty PCB
- Blocked condensate pipe or flue
- Blocked trap or condensate drain pipe work
- Faulty gas valve
- Low gas pressure
- Blocked condensate/trap
- Flue components not correctly assembled, fixed or supported
- Flue or flue terminal obstructed
- Seals on flue extensions displaced during installation
- Combustion products and inlet air mixing due to flue integrity fault
- Gas control valve fault requiring replacement
- Spark generator fault requiring replacement
- Faulty spark generator causing ignition failure
- CO/CO2 ratio greater than 0.004 indicates need for cleaning
- Debris or deposits in heat engine/sump outlet
- Damaged electrode affecting combustion
- Condensate trap blockage or drying out
- Combustion deposits building up on heat exchanger
- Damaged or worn electrode affecting spark gap
- Debris in sump outlet or condensate trap
- Water or gas joint leakage
- Faulty gas control valve requiring replacement
Where to start
- Check if boiler ignites for a short time and then extinguishes
- Check Gas Pressure available at the Boiler Inlet (>18 mbar)
- Check if 24Vdc supply is available at the Gas Valve while the flame is on
The full answer, free
- 62 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 51), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
From the Ideal manual for the Logic System IE Gen 2. Check the model on the data plate before you order parts.
Other Ideal Logic System IE Gen 2 fault codes
- F03Fan fault
- F04Flow thermistor fault
- F05Return thermistor fault
- F06Outside sensor fault
- F09PCB fault
- F0DLow water flow / low water pressure
- F0TRoom thermostat fault
- F0UFlow/return differential greater than 50°C
- F10Spark generator fault
- F12Pump rotor blocked
- F13Pump fault
- F15Pump fault
- F16Gas valve fault
- F17Pump fault
- L01Flow temperature overheat lockout
- L04Flow thermistor fault
- L05Return thermistor fault
- L06False flame lockout (flame on before gas valve on)
- L0CRepeated restart lockout
- L0DIgnition lockout: blocked flue/condensate