Ideal Logic System IE Gen 2 fault F16
Gas valve fault
Gas boilerWhat it means
Fault indicating an issue with the gas valve or its wiring.
Likely causes
- Faulty gas valve wiring
- Faulty gas valve
- Low gas pressure
- Gas valve wiring/PCB fault
- Faulty spark generator causing ignition failure
- Faulty electrode
- Blocked condensate/trap
- Flue components not correctly assembled, fixed or supported
- Flue or flue terminal obstructed
- Seals on flue extensions displaced during installation
- Combustion products and inlet air mixing due to flue integrity fault
- Gas control valve fault requiring replacement
- Spark generator fault requiring replacement
- CO/CO2 ratio greater than 0.004 indicates need for cleaning
- Debris or deposits in heat engine/sump outlet
- Damaged electrode affecting combustion
- Condensate trap blockage or drying out
- Combustion deposits building up on heat exchanger
- Damaged or worn electrode affecting spark gap
- Debris in sump outlet or condensate trap
- Water or gas joint leakage
- Faulty gas control valve requiring replacement
Where to start
- Check gas valve wiring
- Restart boiler and check if it ignites briefly then extinguishes
- Check gas pressure at boiler inlet is >18 mbar
The full answer, free
- 59 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 49), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
From the Ideal manual for the Logic System IE Gen 2. Check the model on the data plate before you order parts.
Other Ideal Logic System IE Gen 2 fault codes
- F02Flame loss
- F03Fan fault
- F04Flow thermistor fault
- F05Return thermistor fault
- F06Outside sensor fault
- F09PCB fault
- F0DLow water flow / low water pressure
- F0TRoom thermostat fault
- F0UFlow/return differential greater than 50°C
- F10Spark generator fault
- F12Pump rotor blocked
- F13Pump fault
- F15Pump fault
- F17Pump fault
- L01Flow temperature overheat lockout
- L04Flow thermistor fault
- L05Return thermistor fault
- L06False flame lockout (flame on before gas valve on)
- L0CRepeated restart lockout
- L0DIgnition lockout: blocked flue/condensate