Ideal Logic System IE Gen 2 fault F0D

Low water flow / low water pressure

Gas boiler

What it means

Fault indicating low water pressure in the boiler/CH system, possibly due to unfilled system or faulty pressure switch.

Likely causes

  1. Pump not rotating freely
  2. Isolation valves closed
  3. Pump not operating
  4. Pump not operating (wiring fault or pump failure)

Where to start

  1. Verify all isolation, system filter and radiator valves are open
  2. Check pump rotates freely and re-measure differential
  3. Check if isolation valves are open

The full answer, free

  • 14 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 51), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Ideal manual for the Logic System IE Gen 2. Check the model on the data plate before you order parts.

Other Ideal Logic System IE Gen 2 fault codes