Ideal Logic System IE Gen 2 fault F10
Spark generator fault
Gas boilerWhat it means
Fault indicating an issue with the spark generator or its wiring.
Likely causes
- Faulty spark generator wiring
- Faulty spark generator causing ignition failure
- Low gas pressure
- Gas valve wiring/PCB fault
- Faulty gas valve
- Faulty electrode
- Blocked condensate/trap
- Boiler mode set to Off
- CH Timer or Room Thermostat switched off
- Closed radiator valves
- No voltage supplied from Timer/Room Stat to SL1 IN (external wiring fault, not boiler fault)
- Missing link wire across OpenTherm connections when no OpenTherm Room Stat connected
- No 230V at SL2 IN when Outside Sensor connected
- Faulty wiring from terminal strip to PCB
- Cylinder stat not calling for heat
- DHW timer switched off
- OFF shown under Tap symbol (DHW mode disabled)
- No 230V present at point (A)
- Outside Sensor wiring fault from terminal strip to PCB
- OFF shown under Tap symbol on display
- System controls or wiring fault
- Spark generator fault requiring replacement
Where to start
- Check wiring from terminal strip to PCB
- Restart boiler and check if it ignites briefly then extinguishes
- Check gas pressure at boiler inlet is >18 mbar
The full answer, free
- 19 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 49), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
From the Ideal manual for the Logic System IE Gen 2. Check the model on the data plate before you order parts.
Other Ideal Logic System IE Gen 2 fault codes
- F02Flame loss
- F03Fan fault
- F04Flow thermistor fault
- F05Return thermistor fault
- F06Outside sensor fault
- F09PCB fault
- F0DLow water flow / low water pressure
- F0TRoom thermostat fault
- F0UFlow/return differential greater than 50°C
- F12Pump rotor blocked
- F13Pump fault
- F15Pump fault
- F16Gas valve fault
- F17Pump fault
- L01Flow temperature overheat lockout
- L04Flow thermistor fault
- L05Return thermistor fault
- L06False flame lockout (flame on before gas valve on)
- L0CRepeated restart lockout
- L0DIgnition lockout: blocked flue/condensate