Ideal Logic System IE fault F5

Return thermistor fault

Gas boiler

What it means

Fault detected with the return thermistor.

Likely causes

  1. Faulty Return Thermistor
  2. Loss of continuity between PCB and Thermistor
  3. Faulty wiring
  4. Return thermistor fault

Where to start

  1. Remove the Return Thermistor from the CH Return Pipe and disconnect the wires.
  2. Check the resistance using a suitable multimeter connected across the thermistor's terminal pins.
  3. Is the Thermistor value correct? If NO, fit a new Thermistor.

The full answer, free

  • 4 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 54), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Ideal manual for the Logic System IE. Check the model on the data plate before you order parts.