Midea Heat pump fault HF
Outdoor unit EEPROM error
Heat pumpWhat it means
The driving program of inverter PCB is detected as being mismatched with Dip switch settings
Likely causes
- Dip switch S5/S6 set incorrectly for the unit capacity/phase
- Main Control PCB failure
- Inverter control box failure
- Faulty inverter power module
- Faulty three-phase bridge rectifier (3Ph models)
- Abnormal state detected requiring compressor protection
- Set temperature reached (normal stop)
- Abnormal system state detected
Where to start
- Check and set the Dip switch to the correct position for the unit model
- Re-power the unit after 20s and check if error still displays
- If error persists, replace Main Control PCB and check if error still occurs
The full answer, free
- 15 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 152), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Midea manual for the Heat pump. Check the model on the data plate before you order parts.
Other Midea Heat pump fault codes
- BAT4 sensor out of operation range protection
- C2IBH (internal backup heater) related fault
- C7Over-high temperature protection for IPM module
- D0Oil return operation active
- E0Water flow failure
- E1Phase loss or phase reversal
- E5T3 outdoor unit heat exchanger bottom temperature sensor error
- E6T4 ambient temperature sensor error
- E8Water flow protection
- E9Th return-air temperature sensor error
- EALow discharge temperature protection
- ECT5_2 water tank temperature sensor error (reserved)
- F1Protection for DC bus undervoltage
- F75Protection for insufficient discharge overheating degree
- FC1TL outdoor unit heat exchanger outlet temperature sensor error
- H1Communication error between main control PCB and inverter PCB
- H2T2 plate heat exchanger outlet refrigerant temperature sensor error
- H3T2B plate heat exchanger inlet refrigerant temperature sensor error
- H4Repeated L1* protection (3 times in 60 mins)
- H5Ta room temperature sensor error
- H6DC fan motor protection
- H7Compressor voltage protection
- H8H-SEN high pressure sensor error
- H9Tw2 zone 2 water flow temperature sensor error