Vaillant Gas boiler fault S.93

Flue gas measurement not possible

Gas boiler

What it means

Flue gas analysis is not currently possible.

Likely causes

  1. Leak in flue system
  2. Flue gas recirculation in extended flue gas installations
  3. Incorrect flue fall causing condensate to not drain back to boiler
  4. Condensate pooling in flue leading to blockage or corrosion
  5. Use of mineral-oil-based grease on flue pipe seals causing seal damage
  6. Air/flue pipe not completely installed
  7. Front casing not installed/closed
  8. Empty condensate trap / siphon allowing flue gas into room air
  9. Damaged seals due to use of grease instead of water/soft soap during installation

Where to start

  1. Check the flue gas installation is intact in accordance with the latest gas safe technical bulletin and installation instructions
  2. For extended flue gas installations, check for flue gas recirculation using the air analysis point
  3. Use a flue gas analyser

The full answer, free

  • 9 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 59), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Vaillant manual for the Gas boiler. Check the model on the data plate before you order parts.