Daikin Altherma fault C4-00

Heat exchanger temperature sensor problem

Heat pump

What it means

Refrigerant liquid thermistor detects an open or short circuit during compressor operation.

Likely causes

  1. Faulty refrigerant liquid thermistor
  2. Faulty hydro PCB
  3. Faulty room thermistor
  4. Deviation of thermistor (higher temperature measured than actual).
  5. Bad contact between sensor and pipe
  6. Deviation of outlet water after backup heater thermistor (lower temperature measured than actual)
  7. Deviation of thermistor (lower temperature measured than actual)
  8. Incorrect refrigerant charge
  9. Faulty expansion valve control
  10. Faulty suction thermistor
  11. Blockages in refrigerant circuit
  12. Faulty discharge pipe thermistor
  13. Domestic hot water tank thermistor measures a higher temperature than actual (component failure)
  14. Incorrect or missing software on the PCB

Where to start

  1. Perform a check of the refrigerant liquid thermistor
  2. Perform a check of the hydro PCB
  3. If all procedures listed above have been performed and the problem is still present, contact the helpdesk

The full answer, free

  • 19 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 34), right under the answer

Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

From the Daikin manual for the Altherma. Check the model on the data plate before you order parts.