Daikin Altherma fault E1-00

Outdoor unit: PCB defect

Heat pump

What it means

Main PCB detects that EEPROM is abnormal.

Likely causes

  1. Faulty main PCB
  2. Faulty or disturbance of the power supply (power supply MUST be within range of nominal operating voltage ±4%)
  3. Power drop
  4. Short circuit
  5. Faulty outdoor unit fan motor
  6. Faulty compressor or miswiring of the compressor power supply cable
  7. Faulty room thermistor
  8. Main PCB software fault
  9. Main PCB failure
  10. Deviation of thermistor (higher temperature measured than actual)

Where to start

  1. Perform a check of the main PCB
  2. Check if the power supply is compliant with the regulations
  3. Perform a check of the outdoor unit fan motor

The full answer, free

  • 13 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 37), right under the answer

Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.