ECA ARCEUS fault E80
Surface type NTC related fault
Gas boilerFree account: 20 more checks, the readings and the manual page (page 45). No card needed.See the full E80 answer
What it means
Associated with the Surface Type NTC sensor which measures the central heating supply and return water temperatures. Malfunction causes the central heating not to work properly, not heat up, or overheat beyond the set temperature.
Likely causes
- Plate exchanger leakage
- Scale buildup inside plate exchanger causing inefficient heat transfer
- Pump electrical connection fault
- Pump motor burned out (short-circuit)
- Air purge failure on pump causing installation pressure decrease
- Surface Type NTC out-of-range resistance / sensor failure
- Dead resistor
- Dead cable to resistor
- Faulty contactor
- Blocked heater installation/plumbing
- Motorised valve not sending water to heater circuit
- Incorrect NTC temperature measurement (supply/return)
- Faulty relay board
- Faulty mainboard
Where to start
- Visually inspect the plate exchanger for water leakage
- Check whether there is a drop in the water pressure in the installation when the domestic water is turned on
- Visual inspection of pump electrical connection
The full answer, free
- 20 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 45), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full E80 fix, readings and manual page. Free.See the full answer
From the ECA manual for the ARCEUS. Check the model on the data plate before you order parts.
Other ECA ARCEUS fault codes
- E03Overheat thermostat trip
- E04Associated with contactor malfunction
- E13Too frequent error reset error
- F33Surface type NTC related fault
- F34Low voltage error
- F35Surface type NTC related fault
- F39Outdoor temperature sensor error
- F47Water pressure sensor fault
- F50Solar energy boiler tank temperature sensor error
- F51Solar panel temperature sensor (PT1000) error
- F52Submersion type NTC (DHW outlet temperature sensor) fault