ECA ARCEUS fault F47

Water pressure sensor fault

Gas boiler
Free account: 2 more checks and the manual page (page 49). No card needed.See the full F47 answer

What it means

Low or high pressure error related to water pressure sensor; a value different from actual water pressure may be displayed on user screen, or pressure rise may not be detected after filling installation with water.

Likely causes

  1. Short-circuit of pressure sensor
  2. Open-circuit of pressure sensor
  3. Damaged pressure sensor
  4. Damaged or loose cable connections on water pressure sensor
  5. Clogged water inlet hole of water pressure sensor
  6. Faulty water pressure sensor voltage output

Where to start

  1. Check the cabling of the pressure sensor.
  2. If all cables are connected and undamaged, replace the pressure sensor.
  3. Check that the cable connections to the water pressure sensor are solid and undamaged

The full answer, free

  • 2 more checks in order
  • How to put it right, step by step
  • The manual page for this fault (page 49), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full F47 fix, readings and manual page. Free.See the full answer

From the ECA manual for the ARCEUS. Check the model on the data plate before you order parts.