ECA ARCEUS fault F50
Solar energy boiler tank temperature sensor error
Gas boilerFree account: 1 more check, the readings and the manual page (page 16). No card needed.See the full F50 answer
What it means
Received if the solar energy boiler tank temperature sensor is short-circuit, open-circuit, or damaged. Domestic water and central heating request is stopped. When this error is deleted, normal operation begins.
Likely causes
- Short-circuit of boiler tank temperature sensor
- Open-circuit of sensor
- Damaged sensor
- Incorrect P00 parameter setting when boiler/solar tank not in use
Where to start
- Reset the error.
- If the error persists after reset and boiler or solar energy tank is not used, make sure P00 parameter is not 2, 3 or 4.
- If using boiler or solar energy tank, make sure the cabling of the temperature sensor is undamaged and assembled.
The full answer, free
- 1 more check in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 16), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full F50 fix, readings and manual page. Free.See the full answer
From the ECA manual for the ARCEUS. Check the model on the data plate before you order parts.
Other ECA ARCEUS fault codes
- E03Overheat thermostat trip
- E04Associated with contactor malfunction
- E13Too frequent error reset error
- E80Surface type NTC related fault
- F33Surface type NTC related fault
- F34Low voltage error
- F35Surface type NTC related fault
- F39Outdoor temperature sensor error
- F47Water pressure sensor fault
- F51Solar panel temperature sensor (PT1000) error
- F52Submersion type NTC (DHW outlet temperature sensor) fault