ECA ARCEUS fault F52
Submersion type NTC (DHW outlet temperature sensor) fault
Gas boilerFree account: 1 more check, the readings and the manual page (page 46). No card needed.See the full F52 answer
What it means
The NTC measures the temperature of the water taken from the domestic water outlet. F52 is associated with malfunction of this sensor, resulting in inability to detect or control DHW temperature correctly.
Likely causes
- NTC sensor out of resistance tolerance for ambient/water temperature
- Damaged or disconnected NTC electrical connections
Where to start
- Disconnect and remove the NTC electrical connections
- Measure the resistance between the NTC terminals using a multimeter
- Compare measured resistance to the resistance table for the corresponding ambient temperature
The full answer, free
- 1 more check in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 46), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full F52 fix, readings and manual page. Free.See the full answer
From the ECA manual for the ARCEUS. Check the model on the data plate before you order parts.
Other ECA ARCEUS fault codes
- E03Overheat thermostat trip
- E04Associated with contactor malfunction
- E13Too frequent error reset error
- E80Surface type NTC related fault
- F33Surface type NTC related fault
- F34Low voltage error
- F35Surface type NTC related fault
- F39Outdoor temperature sensor error
- F47Water pressure sensor fault
- F50Solar energy boiler tank temperature sensor error
- F51Solar panel temperature sensor (PT1000) error