What it means

Associated with the Surface Type NTC sensor which measures the central heating supply and return water temperatures. Malfunction causes the central heating not to work properly, not heat up, or overheat beyond the set temperature.

Likely causes

  1. NTC cables not plugged in
  2. Damaged or broken NTC cables
  3. NTC resistance value out of specification
  4. Faulty return water NTC sensor
  5. Faulty mainboard
  6. Surface Type NTC out-of-range resistance / sensor failure

Where to start

  1. Make sure the NTC cables in the return water line are plugged in.
  2. If the cables are plugged in, check the cables end-to-end. Make sure the cables are undamaged and plugged into the mainboard terminal.
  3. If there is a damaged wire, replace the low voltage cable group.

The full answer, free

  • 7 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 45), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full F33 fix, readings and manual page. Free.See the full answer

From the ECA manual for the ARCEUS. Check the model on the data plate before you order parts.