Grundfos STP 2 fault 4

Pompa sürekli olarak çalışıyor (positive displacement pumps)

Shower pump

What it means

Pump runs continuously on positive pressure pumps.

Likely causes

  1. Sistemde hava vardır (Air in system)
  2. Akış anahtarı şamandırası (açık) pozisyonda kalmıştır (Flow switch float stuck in open position)
  3. Akış anahtarı veya reed anahtarı arızalıdır veya yanlış ayarlanmıştır (Flow switch or reed switch faulty or incorrectly set)
  4. Mechanical stress on pump from rigid pipe connection
  5. Mechanical strain on pump from misaligned pipework
  6. Solder joint heat damaging plastic pump components
  7. Air pockets from incorrectly routed pipework
  8. Additional outlet fittings on inlet pipework causing incorrect flow switch operation

Where to start

  1. Verify pump switch remains in 'I/ON' position at all times during normal operation
  2. Allow maximum water flow with pump not running (e.g., remove shower head from hose)
  3. Turn on power supply, run pump for a few minutes, turn off power, drain water and clean suction filters

The full answer, free

  • 17 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 28), right under the answer

Safety: Isolate power and water, and prove dead before you open or test the pump.

From the Grundfos manual for the STP 2. Check the model on the data plate before you order parts.