Grundfos STP 2 fault 8

Hortum bağlantısında sızıntı var (positive displacement pumps)

Shower pump

What it means

Leak at hose connection on positive pressure pumps.

Likely causes

  1. Hortum bağlantısı gevşemiştir (Hose connection loose)
  2. Mechanical stress on pump from rigid pipe connection
  3. Leaks from use of jointing compound instead of correct hose connections
  4. Leaks due to insufficient hose insertion depth
  5. Leaks due to under-tightened or incorrectly connected hoses
  6. Mechanical strain on pump from misaligned pipework

Where to start

  1. STR2 ve SSR2: Hortum rondelalarının ve filtre rondelalarının takılı olduğunu kontrol edin
  2. STP, SSP: Hortum bağlantısının minimum 33 mm derine tamamen sokulduğunu kontrol edin
  3. Verify hose inserted to minimum 33 mm depth.

The full answer, free

  • 10 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 28), right under the answer

Safety: Isolate power and water, and prove dead before you open or test the pump.

From the Grundfos manual for the STP 2. Check the model on the data plate before you order parts.