Midea R32 M thermal Arctic Mono fault EB
Solar board sensor tsolar error
Heat pumpWhat it means
Solar board sensor Tsolar error (serial number 12). Displayed on user interface and hydronic system main PCB.
Likely causes
- Sensor Tsolar disconnected, sensor malfunction, wiring break, PCB connection issue
- Temperature sensor not connected properly or has malfunctioned. Damaged hydronic system main PCB.
- Sensor Tsolar fault
- Sensor wiring fault
Where to start
- Check sensor Tsolar connection, measure sensor resistance, verify wiring continuity, test sensor response
- Identify sensor type based on fault code
- Locate corresponding port on hydronic system main PCB
The full answer, free
- 1 more check in order
- The manual page for this fault (page 66), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Midea manual for the R32 M thermal Arctic Mono. Check the model on the data plate before you order parts.
Other Midea R32 M thermal Arctic Mono fault codes
- BHPED board checking fail
- C7Transducer module temperature too high protect
- D0Oil return operation in progress
- E0Water flow failure (repeated E8 occurrence)
- E1Phase sequence error
- E2Communication error between outdoor unit and user interface
- E3Backup electric heater water outlet temperature sensor error
- E4Domestic hot water tank temperature sensor error
- E5Air side heat exchanger refrigerant outlet temperature sensor error
- E6Outdoor ambient temperature sensor error
- E7Balance tank sensor Tbt1 error
- E8Water flow failure
- E9Suction pipe temperature sensor error
- EADischarge pipe temperature sensor error
- ECBalance tank sensor Tbt2 error
- EDWater side heat exchanger water inlet temperature sensor error
- EEHydronic system EEPROM error
- ELCommunication fault between hydraulic module and MH-kit
- F1DC bus voltage is too low
- H0Communication error between refrigerant system main control chip and hydronic system...
- H1Communication error between refrigerant system main control chip and inverter driver chip
- H2Water side heat exchanger refrigerant inlet (liquid pipe) temperature sensor error
- H3Water side heat exchanger refrigerant outlet temperature sensor error
- H5Room temperature sensor error