Ideal Logic Heat fault C2

BCC fault (boiler chip card)

Gas boiler
Free account: the readings and the manual page (page 53). No card needed.See the full C2 answer

What it means

The boiler chip card is wrong for this boiler or is faulty.

Likely causes

  1. Wrong BCC fitted for the boiler range or output.
  2. BCC not inserted securely.
  3. BCC faulty.

Where to start

  1. Check the correct BCC for the boiler is fitted (read the label on the BCC).
  2. Check the BCC is pushed fully into the PCB slot.
  3. If c2 is still shown after a reset, replace the BCC with a new correct one and reset the boiler.

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 53), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full C2 fix, readings and manual page. Free.See the full answer

From the Ideal manual for the Logic Heat. Check the model on the data plate before you order parts.

Other Ideal Logic Heat fault codes