Ideal Logic Heat fault L1

Flow temperature overheat lockout

Gas boiler
Free account: 3 more checks, the readings and the manual page (page 51). No card needed.See the full L1 answer

What it means

The flow temperature has gone past its safe limit and the boiler has locked out. It needs a manual reset.

Likely causes

  1. System not filled with water.
  2. Isolation or radiator valves closed.
  3. Pump not wired back to the boiler.
  4. Pump not rotating freely.
  5. Flow/return differential above 30°C.
  6. Flow thermistor fault.

Where to start

  1. Check the boiler and CH system are full of water.
  2. Check all isolation and radiator valves are open.
  3. Check the pump is wired back to the boiler (page 51).

The full answer, free

  • 3 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 51), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full L1 fix, readings and manual page. Free.See the full answer

From the Ideal manual for the Logic Heat. Check the model on the data plate before you order parts.