Ideal Logic Heat fault F2
Flame loss
Gas boilerFree account: 5 more checks, the readings and the manual page (page 52). No card needed.See the full F2 answer
What it means
The boiler lit but then lost the flame during operation.
Likely causes
- Gas pressure below 18 mbar at the boiler inlet.
- Detection electrode fault or contamination.
- Condensate pipe blocked.
- Flue blocked.
- Spark generator fault.
- Ignition electrode fault.
- Gas valve fault.
- Siphon or condensate drain blocked.
Where to start
- Check the gas pressure at the boiler inlet test point: minimum 18 mbar.
- Check the detection electrode for continuity, condition and position.
- Check the condensate pipe for a blockage.
The full answer, free
- 5 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 52), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full F2 fix, readings and manual page. Free.See the full answer
From the Ideal manual for the Logic Heat. Check the model on the data plate before you order parts.