Ideal Logic Heat fault L-C

Ignition failure lockout

Gas boiler
Free account: 2 more checks, the readings and the manual page (page 36). No card needed.See the full L-C answer

What it means

The boiler has failed to light after 5 ignition attempts and has locked out; the display shows L-C constantly. It needs a manual reset.

Likely causes

  1. Gas supply not reaching the burner.
  2. Ignition electrode fault.
  3. Flame sensor fault.
  4. Gas valve malfunction.
  5. Air in the gas line.

Where to start

  1. Check the gas service cock is open.
  2. Check the gas supply pressure at the inlet test point.
  3. Check the ignition sequence is taking place.

The full answer, free

  • 2 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 36), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.