Ideal Logic Heat fault FD

No water flow

Gas boiler
Free account: 2 more checks, the readings and the manual page (page 53). No card needed.See the full FD answer

What it means

The water flow sensor is seeing no circulation through the boiler.

Likely causes

  1. System not filled with water.
  2. Isolation or radiator valves closed.
  3. Pump not rotating.
  4. Pump electrical connection fault.
  5. Water flow sensor connector loose.
  6. Water flow sensor faulty.

Where to start

  1. Check the boiler and CH system are full of water.
  2. Check all isolation and radiator valves are open.
  3. Turn the power off and on and check whether the pump turns.

The full answer, free

  • 2 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 53), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full FD fix, readings and manual page. Free.See the full answer

From the Ideal manual for the Logic Heat. Check the model on the data plate before you order parts.