LG Therma V fault CH62
Heat sink temp, high error
Heat pumpWhat it means
The heat sink detection temperature is over 85°C, indicating the inverter module (IPM/PFCM/IGBTM) is overheating.
Likely causes
- Inverter board power module connection status is bad.
- The fan motor of the outdoor unit operates abnormally.
- The inverter board of the outdoor unit is defective.
- Overload operation.
- Fan locked
- Obstruction/shield around the heat exchanger
- Insufficient distance between product and wall
- Piping condition issues such as pipe bending
- EEV operation/connection status fault
- Abnormal refrigerant pressure
- Compressor restraint
- Compressor wiring reverse phase loss
- Short circuit or opening of internal connection line in compressor
- Compressor winding resistance out of spec
- Compressor insulation resistance failure
- Inverter PCB assembly or connector connection fault
- IGBTM failure
- Incorrect FCU setting mismatched to actual installation can cause abnormal operation
- FCU set to 'Use' when not actually installed causes unit to stop unnecessarily
- FCU set to 'Not use' when FCU is actually installed means Stop temp. is ignored and unit will not stop, risking condensation
Where to start
- Check if the screw torque of IPM, PFCM is good. If No, tighten the screw of IPM, IGBTM.
- If screw torque is good (Yes), check if the thermal grease of IPM, IGBTM is normal and if IPM, IGBTM are normal. If No, change the Inverter PCB.
- If thermal grease and IPM/IGBTM are normal (Yes), recheck power and installation condition.
The full answer, free
- 12 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 122), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the LG manual for the Therma V. Check the model on the data plate before you order parts.
Other LG Therma V fault codes
- 03Communication error between indoor unit and wired remote controller
- 05Communication error between main PCB(indoor) and main PCB(outdoor cycle)
- 14Problem in flow rate
- 15Overheating of water pipe
- 232Problem in flow sensor
- 26No position error
- 29Comp over current
- 40Inv comp CT sensor error
- 52Inv PCB(outdoor) - main PCB(outdoor cycle) communication error
- 53Main PCB(indoor) - main PCB(outdoor) communication error
- 57Main PCB(indoor) → inv PCB(outdoor) communication error
- 60Outdoor EEPROM error
- 67Fan lock error
- CH01Room air temperature sensor fault
- CH02Inlet pipe temperature sensor fault
- CH03Bad communication between remote controller and indoor unit
- CH05Bad communication between outdoor unit and indoor unit
- CH08DHW tank temperature sensor fault
- CH09PCB program (EEPROM) fault
- CH114Injection in sensor error
- CH115Injection out sensor error
- CH13DHW tank temperature sensor fault
- CH14Problem in flow rate
- CH15Water pipe strange overheat