Panasonic Aquarea T-CAP R32 fault H12
Connection capability rank abnormality
Heat pumpWhat it means
During startup operation of cooling and heating, the capability rank of the indoor unit as checked by the outdoor unit is used to determine connection capability rank abnormality. The fault is judged if the abnormality continues for 90 seconds.
Likely causes
- Indoor/outdoor capacity mismatch
- Heat pump error triggering backup heat source requirement
- Wrong model interconnected.
- Wrong indoor unit or outdoor unit PCB (main) used.
- Faulty indoor unit or outdoor unit PCB (main).
Where to start
- Confirm Force heater request ON by user OR auto turn ON by remote controller during error
- Check latest mode selection sent by remote controller (heat/cool/tank)
- Check indoor and outdoor units model number.
The full answer, free
- 14 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 166), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Panasonic manual for the Aquarea T-CAP R32. Check the model on the data plate before you order parts.
Other Panasonic Aquarea T-CAP R32 fault codes
- F12Outdoor high pressure switch activate
- F15Outdoor fan motor (DC motor) mechanism locked
- F16Input over current detection
- F20Compressor overheating
- F22IPM overheating
- F23Output over current detection
- F24Refrigeration cycle abnormality
- F25Four way valve abnormality
- F30Indoor water outlet temperature sensor 2 abnormality
- F36Outdoor air temperature sensor abnormality
- F37Indoor water inlet temperature sensor abnormality
- F40Outdoor discharge pipe temperature sensor abnormality
- F41Power factor correction (PFC) abnormality
- F42Outdoor pipe temperature sensor abnormality
- F43Outdoor defrost temperature sensor abnormality
- F45Indoor water outlet temperature sensor abnormality
- F46Outdoor current transformer open circuit
- H15Compressor tank temperature sensor abnormality
- H20Water pump abnormality
- H23Indoor refrigerant liquid temperature sensor abnormality
- H27Service valve error
- H28Abnormal solar sensor
- H31Abnormal swimming pool sensor
- H36Abnormal buffer tank sensor