Panasonic Aquarea T-CAP R32 fault H15
Compressor tank temperature sensor abnormality
Heat pumpWhat it means
During startup and operation of cooling and heating, the temperatures detected by the compressor tank temperature sensor are used to determine sensor error. The fault is judged if the abnormality continues for 5 seconds.
Likely causes
- Compressor temperature sensor defective or disconnected
- Faulty connector connection.
- Faulty sensor.
- Faulty outdoor unit PCB (main).
Where to start
- Check the CN-TANK connector connection: Turn OFF the power, check the connector connection.
- Check the CN-TANK connector connection for poor contact
- Measure resistance of compressor tank temperature sensor after disconnecting from outdoor unit PCB (main).
The full answer, free
- 18 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 167), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Panasonic manual for the Aquarea T-CAP R32. Check the model on the data plate before you order parts.
Other Panasonic Aquarea T-CAP R32 fault codes
- F12Outdoor high pressure switch activate
- F15Outdoor fan motor (DC motor) mechanism locked
- F16Input over current detection
- F20Compressor overheating
- F22IPM overheating
- F23Output over current detection
- F24Refrigeration cycle abnormality
- F25Four way valve abnormality
- F30Indoor water outlet temperature sensor 2 abnormality
- F36Outdoor air temperature sensor abnormality
- F37Indoor water inlet temperature sensor abnormality
- F40Outdoor discharge pipe temperature sensor abnormality
- F41Power factor correction (PFC) abnormality
- F42Outdoor pipe temperature sensor abnormality
- F43Outdoor defrost temperature sensor abnormality
- F45Indoor water outlet temperature sensor abnormality
- F46Outdoor current transformer open circuit
- H12Connection capability rank abnormality
- H20Water pump abnormality
- H23Indoor refrigerant liquid temperature sensor abnormality
- H27Service valve error
- H28Abnormal solar sensor
- H31Abnormal swimming pool sensor
- H36Abnormal buffer tank sensor