Worcester Bosch Greenstar 8000 fault 1065

System pressure sensor faulty or not connected

Gas boiler
Free account: 1 more check, the readings and the manual page (page 77). No card needed.See the full 1065 answer

What it means

Fault (category B): the system water pressure sensor is faulty or its plug is off.

Likely causes

  1. Pressure sensor plug not connected.
  2. Harness continuity failure.
  3. Faulty sensor supply voltage or return signal.

Where to start

  1. Check the water pressure sensor plug is connected.
  2. Plug the connector onto the water pressure sensor correctly.
  3. Check the continuity of the harness.

The full answer, free

  • 1 more check in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 77), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 1065 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar 8000. Check the model on the data plate before you order parts.