Fan shut down during safety time

Gas boiler
Free account: 2 more checks, the readings and the manual page (page 74). No card needed.See the full 214 answer

What it means

Locking fault (category V): the fan stopped during the safety time of the ignition sequence.

Likely causes

  1. Fan voltage supply fault.
  2. Fan harness continuity fault.
  3. Fan power modulation fault.
  4. Defective PCB.

Where to start

  1. Reset the appliance.
  2. Create a heat demand and see if the boiler fires.
  3. Check the voltage to the fan and the continuity of the fan harness.

The full answer, free

  • 2 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 74), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 214 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar 8000. Check the model on the data plate before you order parts.