Worcester Bosch Greenstar 8000 fault 232

Boiler locked by external switching contact

Gas boiler
Free account: 3 more checks, the readings and the manual page (page 75). No card needed.See the full 232 answer

What it means

The boiler is locked by an external switching contact, for example the safety contact on a condensate lifting pump or an external temperature monitor.

Likely causes

  1. Connection plug for the external switch contact not plugged into the PCB.
  2. No feedback voltage at the external safety contact on the condensate lifting pump, which blocks the boiler.
  3. Switching point of the external temperature monitor set too low.
  4. Connection cable to the external temperature monitor damaged.
  5. External temperature monitor defective.

Where to start

  1. Make sure nothing is plugged into the red I3 connection (the external cut-off switch is not used in the UK).
  2. Check the connection plug for the external switch contact is plugged into the PCB.
  3. Check the feedback voltage at the external safety contact on the condensate lifting pump.

The full answer, free

  • 3 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 75), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 232 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar 8000. Check the model on the data plate before you order parts.

Other Worcester Bosch Greenstar 8000 fault codes