Worcester Bosch Greenstar 8000 fault codes

48 codes from the Worcester Bosch manual for the Greenstar 8000 gas boiler. Pick one for what it means, the likely causes and where to start.

CodeWhat it means
1010No communication via EMS BUS connection
1021Cylinder charging or hot water temperature sensor faulty
1037Outside temp. sensor faulty - heating backup operation active
1065System pressure sensor faulty or not connected
1068Outside temp. sensor or lambda probe faulty
1076Heat exchanger temp sensor disconnected
2085Internal fault
214Fan shut down during safety time
224Maximal flue gas thermostat or heat exchanger maximal thermostat has activated
228Flame signal without flame present
229Flame failed during burner operation
232Boiler locked by external switching contact
234Gas valve electrical fault
238Boiler electronics faulty
244System fault boiler electronics / basic controller
245System fault boiler electronics / basic controller
249System fault boiler electronics / basic controller
250System fault boiler electronics / basic controller
251System fault boiler electronics / basic controller
252System fault boiler electronics / basic controller
253System fault boiler electronics / basic controller
254System fault boiler electronics / basic controller
257System fault boiler electronics / basic controller
258System fault boiler electronics / basic controller
259System fault boiler electronics / basic controller
262System fault boiler electronics / basic controller
263System fault boiler electronics / basic controller
281Pump stuck or running in air
2910Fault in flue system
2923Boiler electr. system fault
2924Boiler electr. system fault
2925Boiler electr. system fault
2926Boiler electr. system fault
2927Boiler electr. system fault
2946Incorrect code plug detected
2948No flame signal with low output
2949No flame signal with high output
2950No flame signal following starting procedure
2951Loss of flame too many times
2961No fan signal available
2962No fan signal available
2963The heat exchanger sensor or both supply and heat exchanger sensors are defective
2965Flow temperature too high
2966Flow temperature rise in heat exchanger too rapid
2970Pressure drop in heating system too rapid
306Flame signal after closing the fuel supply
363System fault boiler electronics / basic controller
815Low loss header temp. sensor faulty