Worcester Bosch Greenstar 8000 fault 1076

Heat exchanger temp sensor disconnected

Gas boiler
Free account: the readings and the manual page (page 77). No card needed.See the full 1076 answer

What it means

Warning (category W): the heat exchanger temperature sensor is disconnected or open circuit.

Likely causes

  1. Sensor plug not connected or poor connection.
  2. Faulty sensor resistance.
  3. Harness continuity failure.
  4. PCB fault.

Where to start

  1. Check the temperature sensor plug is connected.
  2. Check the resistance of the sensor.
  3. Check the continuity of the harness.

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 77), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 1076 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar 8000. Check the model on the data plate before you order parts.