ECA Proteus fault E03

3 way shaft group / motorized valve related fault

Gas boiler
Free account: 21 more checks, the readings and the manual page (page 69). No card needed.See the full E03 answer

What it means

Primary relevant error code associated with faulty operation of the 3-way shaft group, which controls switching between summer (DHW) and winter (CH) modes and provides internal by-pass function.

Likely causes

  1. Boiler remains only in central heating mode
  2. Radiators may get warm in summer mode due to valve fault
  3. Noise from motor during mode changes
  4. Wearing of valve causing heating problems
  5. Dirt or clogging on heat exchanger pipes
  6. Cracks or holes in exchanger pipes causing leakage
  7. Failure to meet heating demand
  8. Isolating valves of boiler closed
  9. No radiator valve open in winter mode
  10. Faulty supply/return water temperature sensors (incorrect resistance)
  11. Internal bypass (3-Way Valve Shaft Group) not functional
  12. Pump connection cables not mounted or loose contact
  13. Clogging in the heating installation
  14. Circulation pump failure
  15. Main board failure
  16. Partial or full clogging of plate heat exchanger
  17. Overheating of central heating system due to internal by-pass failure
  18. Pump cable connection issues
  19. Pump not circulating water correctly
  20. 3-way motorized valve jammed causing boiler to remain in summer or winter mode
  21. Internal by-pass function not functional
  22. Water leakage at 3-way motorized valve connections

Where to start

  1. Check whether cable connections are proper and without damage
  2. Check whether connectors on the 3-way motor are installed properly
  3. Perform voltage testing for central heating and tap water modes

The full answer, free

  • 21 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 69), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full E03 fix, readings and manual page. Free.See the full answer

From the ECA manual for the Proteus. Check the model on the data plate before you order parts.